The Tri-Carb 4910TR liquid scintillation counter provides high performance and flexibility for multi-application and multi-user laboratories detecting radioactivity in life science research, environmental monitoring and/or health physics assays. Optional Packages are available for High Sensitivity Counting of low activity samples and Alpha Beta Separation for unknown or mixed samples.
Standard Features
- TR-LSC (Time-resolved Liquid Scintillation Counting) for high sensitivity, low background liquid scintillation counting
- QuantaSmart¢â Software a robust multitasking, easy networking environment with unlimited assays in a secure multiuser environment
- SpectraWorks 2 spectral analysis package that determines optimal counting regions, and calculates figure of merit automatically
- Replay reanalyzes sample counts without recounting samples
- Dynamic color correction ensures accuracy of tracking lower energy sample spectra over a wide quench range
- Auxiliary Spectrum Memory stores rejected events for future analysis
- Bi-directional sample conveyer with a capacity of up to 408 (20mL vials) or 720 (4 or 7 mL vials)
- Varisette¢â sample cassette for intermixing vial sizes without special adapters
- Operational-status LED indicator for clear assay status updates at a glance
- Luminescence Detection Reporting percent luminescence is flagged on printout to alert user of possible sample problems
- Direct DPM determines single-label DPM in any cocktail without the use of quench standards
- 30 Quick Count protocol flags with the flexibility to define unlimited assays
- Fold-away ergonomic arm adaptable to enter data either sitting or standing
- Built in Computer with Windows 10 Operating System
Physical data
- Dimensions H/W/D 18.5 /40.5/32 in (47/103/81 cm)
- Dimensions with temperature control H/W/D 18.5 /40.5/32 in (47/103/81 cm)
- Weight 477 lb (217 kg)
- Weight with temperature control 523 lb (238 kg)
Additional Options
- Luminescence Correction removes sample counts induced by luminescence in the sample
- High Sensitivity Counting lowers background levels for improved instrument sensitivity
- Enhanced IPA (Instrument Performance Assessment) monitors and reports eight key counting performance metrics for quality assurance and warns of significant changes
- Alpha Beta Separation via PSA Histogram and Dual PSA Discriminators improves accuracy for mixed and unknown samples containing isotopes with overlapping energies